Both produce "no hot water," but the pattern of what you're getting from the tap narrows it down considerably.
On a standard electric tank water heater there are usually two heating elements — one near the top of the tank, one near the bottom — and a thermostat controlling each. They work in sequence: the upper element heats the top of the tank first, then hands off to the lower element to bring the rest up to temperature. Knowing that sequence is what lets you read the symptoms.
If there's nothing warm coming out anywhere in the house, the most common causes are a tripped breaker, a tripped high-temperature limit switch on the unit, or a failed upper thermostat or upper element. Because the upper element is first in the sequence, when it stops working the handoff to the lower one never happens and the whole tank stays cold.
This is the classic lower-element symptom. The upper element is still heating the top portion of the tank, so you get genuinely hot water — just not much of it, and once that top layer is drawn off there's nothing hot behind it. If your showers went from comfortable to cold partway through and nothing else in the house changed, the lower element or its thermostat is the first suspect.
Water that's warm but never properly hot usually points at a thermostat that's out of calibration or set low, or an element that's partially failed. It can also simply be a temperature setting someone adjusted. Worth checking the setting before assuming a part failed.
A thermostat stuck in the closed position keeps calling for heat when it shouldn't, which can drive the tank above its setpoint. This one deserves prompt attention rather than monitoring — scald risk is real, and an over-temperature condition puts stress on the tank and the relief valve.
In hard-water areas sediment settles on the bottom of the tank and buries the lower element, which makes it work harder, run longer, and fail sooner. That's also what produces the popping and rumbling covered in our post on water heater noises, and it's part of why hard water shortens the life of these components locally.
Elements and thermostats are both serviceable parts, and on a tank that's otherwise sound, replacing one is far less than replacing the heater. The judgment call is whether the tank's remaining life justifies it — on a unit already near the end of its expected lifespan, putting parts into it may just be paying twice.
Testing elements and thermostats means opening access panels on a unit wired for 240 volts. Even with the breaker off, confirming a part has actually failed rather than being starved by an upstream fault takes a meter and knowing what reading you're looking for. This is a fast job for someone who does it regularly and a genuinely hazardous one otherwise.
None of the above applies to a gas unit, which has no electric elements — the equivalent symptoms there point at the thermocouple, gas control valve, or pilot assembly. Anything involving the gas control on a tank should go to a licensed technician rather than being worked on at home.
If you're getting a little hot water and then none, no hot water at all with the breaker holding, or water noticeably hotter than the setting, call (209) 860-5004. A licensed plumber can identify which component failed and tell you honestly whether repairing it makes sense for the age of your tank.